Configurable transformer model

The model of the configurable transformer component is based on the ideal transformer shown below: 

configurable transformer model

The figure above shows the model of a dual primary, dual secondary transformer.

Gp1 is a controlled current source while Ep2, Es1 and Es2 are controlled voltage sources. These sources model the ideal power conversion function of the transformer.