Copy of Block 1 - Overvoltage protection (1) (1)

0
Favorite
0
copy
Copy
21
Views
Copy of Block 1 - Overvoltage protection (1) (1)

Circuit Description

Graph image for Copy of Block 1 - Overvoltage protection (1) (1)

Circuit Graph

D1 + D2 set a 38.4V breakvoltage. Once this voltage is surpassed, the transistor Q2 ideally conducts sending the signal OV_Prot. At the same time, Q1 starts to conduct, disabling the zener D2. When this occurs, the circuits becomes normal only when the voltage is lower than 36V (since D2 is disabled).

There are currently no comments

Creator

user-738019

1 Circuit

Date Created

9 months, 1 week ago

Last Modified

9 months, 1 week ago

Tags

This circuit has no tags currently.

Circuit Copied From