4th-Order LC Bandstop Filter.
Fo = 1/[2π√(L·C)]
Fo = 1/[2π√(10 µH · 0.1 µF)]
Fo = 159.155 kHz
Peaking intensifies as R increases. Flat magnitude response outside the rejection band results when R = 10/√2 = 7.071 Ω. In the circuit a quick way to do this is to adjust the total value of R to 10 Ω while keeping the position at 70.71%.